Scientific Devices Turbine Flow Meters are useful for liquids & gases in general industrial application. They provide excellent performance with quality & reliability. Suitable for as hygienic application. The flowing media engages a vaned rotor causing it to rotate at an angular velocity proportional to flow rate. The pick -of coil senses the spinning motion of the rotor inside the pipe & converts it into a pulsating electrical signal. Summation of the pulsating electrical signal is directly related to the total flow. The frequency is linearly proportional to flow rate which is converted to mA signal by electronic circuitry. Flow rate Indicator / Totalizer / Transmitter and Controllers are available in Local/Remote and Panel Mounted Options.
Design & Calibration Conforms to ISO 9104 & ISO DIS 6817.
| Fluid | : | Clean Liquid and Gases |
| Measuring Principle | : | Turbine (measures flow rate based on the rotational speed of a turbine) |
| Line Size Range | : | 15 mm (1/2″) to 150 mm (6″) |
| Rated Pressure | : | Up to 40 bar |
| Rated Temperature | : | -40°C to +150°C |
| Viscosity | : | Maximum 40 cp |
| Body Material | : | AISI SS304 / AISI SS304L / AISI SS316 / AISI SS316L |
| Rotor | : | SS410 (Aero-Dynamic Design) |
| Bearing | : | Tungsten Carbide / Ball Bearing |
| Shaft | : | Tungsten Carbide / Stainless Steel |
| Power Supply | : | 12–32 VDC or 110–230 VAC |
| Output Signal | : | 4–20 mA + HART / RS485 + Pulse |
| Enclosure | : | Die Cast Aluminium (ATEX Certified II 2G Ex d IIC T6 Gb) |
| Cable Entry | : | M20 × 1.5 / 1/2″ NPT |
| Repeatability | : | ±0.1% on FSD |
| Accuracy | : | ±0.5% on FSD |
| Linearity | : | ±0.5% on FSD |
Turbine Flowmeter with Cooling Jacket Field Mounted Flow Rate Indicator
Product Code: TFM-FR-TZ-TX-CJ