An Averaging Pitot Tube measures fluid low by sensing the differential pressure between multiple upstream (total pressure) and downstream (static pressure) ports along its length. Installed across the pipe diameter, it averages the velocity proile for improved accuracy in turbulent or non-uniform low.
The measured differential pressure is proportional to the square of the fluid velocity, which can be converted to volumetric or mass low rate using Bernoulli’s principle and density compensation if required.
| Measurement Principle | : | Differential pressure based on Bernoulli’s principle |
| Sensing Element | : | Square bar averaging pitot tube |
| Process Fluid | : | Liquids, gases, and steam |
| Flow Direction | : | Unidirectional |
| Pipe Size Range | : | 6″ and above (as per design) |
| Accuracy | : | ±1.0% of actual flow |
| Repeatability | : | ±0.1% |
| Rated Pressure | : | Upto 16 Bar |
| Wetted Parts Material | : | SS304 / SS316 / SS316L (optional on request) |
| Process Connection | : | Flanged / Threaded |
| Flange Standard | : | ASME B16.5 / DIN / BS/JIS |
| Mounting Orientation | : | Horizontal or vertical pipelines |
| Pressure Tappings | : | Integral high-pressure and low-pressure ports |
| Permanent Pressure Loss | : | Low |