The Level is sensed via a magnetic float moving alongside
the protection probe that is sub - merged in the liquid. The
Magnetic float tracks the level, magnetically activating an array of
cascaded reed switches. The reed Switches acts as the wiper of a
potentiometer made up by a chain of resistors. The electronics in the
probe housing converts the voltage supplied via the potentiometer into 4
- 20 mA signal.